Conventional Fire Alarm System
Fire Alarm Bell
A clear and powerful audible warning device for conventional fire alarm systems.
View details
Conventional Fire Alarm System
A clear and powerful audible warning device for conventional fire alarm systems.
View details
Product details
The LW5609 Fire Alarm Bell is designed to provide a clear and powerful audible warning when activated by a fire alarm control panel. It helps alert occupants quickly and supports safe evacuation procedures during emergency situations.
| Model | LW5609 |
|---|---|
| Product Type | Fire Alarm Bell |
| Operating Voltage | DC 24V (+10%, -15%) |
| Operating Current | ≤ 20mA |
| Sound Pressure Level | 75–115 dB |
| Dimensions | Ø152 mm |
| Operating Temperature | -10°C to +50°C |
| Relative Humidity | ≤ 95% RH |
| Standard | GA385-2002 |
Conventional Fire Alarm System
A conventional optical smoke detector with real-time monitoring and clear LED status indication.
View details
Product details
The C9030T is a conventional optical smoke detector designed to monitor smoke concentration in real time. During normal operation, the red indicator flashes while the detector continuously monitors the protected area. When the smoke concentration exceeds the preset alarm threshold, the detector enters the alarm condition and the red indicator remains illuminated.
| Model | C9030T |
|---|---|
| Detector Type | Conventional Optical Smoke Detector |
| Wiring Method | Two-wire switch-type smoke-sensing detector |
| Enclosure Material | ABS |
| Relative Humidity | ≤95%, non-condensing |
| Base Type | DZ-903K |
| Status Indication | Red LED indication |
| Alarm Indication | Red LED remains ON during alarm |
| Fault Indication | Red LED flashes twice periodically during sensor fault |
Conventional Fire Alarm System
A resettable manual call point for fast, reliable activation of a conventional fire alarm.
View details
Product details
The C9060T Conventional Manual Call Point is designed to provide a fast and reliable method for manually initiating a fire alarm. When activated, it sends an alarm signal to the fire alarm control panel, allowing building occupants to respond quickly to emergency situations. The unit features a resettable operating element, enabling repeated use after activation.
| Model | C9060T |
|---|---|
| Product Type | Conventional Manual Call Point |
| Standard | EN 54-11 |
| Working Mode | Two-Wire Bus System |
| Operating Voltage | DC 24V |
| Monitoring Current | 0mA |
| Action Current | <30mA |
| Weight | Approx. 105g (with base) |
| Operating Temperature | -10°C to +55°C |
| Relative Humidity | ≤95% (40°C ±2°C, Non-Condensing) |
| Activation Method | Manual Press |
| Reset Method | Special Reset Tool |
| Indicator Status | OFF during normal operation, ON during alarm |
Conventional Fire Alarm System
A combined audible and visual alarm device for conventional fire alarm systems.
View details
Product details
The C9092T Conventional Sounder Beacon is an audible and visual alarm notification device designed for use with conventional fire alarm control panels. It provides both sound and flashing light signals to alert building occupants during fire emergencies, making it particularly effective in areas where visibility may be reduced due to smoke or environmental conditions.
| Model | C9092T |
|---|---|
| Product Type | Conventional Sounder Beacon |
| Standard | EN 54-3 (Type A) |
| Wiring Method | Non-Polarity, Two-Wire |
| Installation Type | Ceiling Mounted |
| Material | Flame Retardant PC/ABS |
| Function | Audible & Visual Alarm Notification |
Conventional Fire Alarm System
A fixed-temperature heat detector for environments where smoke detectors may be unsuitable.
View details
Product details
The C9021T Conventional Heat Detector continuously monitors ambient temperature and activates when the preset threshold is reached. It is particularly suitable for locations where smoke detectors may not perform effectively. It is not recommended where smoldering fires or heavy smoke are expected before a significant temperature increase.
| Model | C9021T |
|---|---|
| Product Type | Conventional Heat Detector |
| Standard | EN 54-5 |
| Detector Category | A2 |
| Static Response Temperature | 54°C to 70°C |
| Operating Voltage | DC 24V (18V–30V) |
| Standby Current | <50µA @ DC 24V |
| Alarm Current | 1mA–20mA @ DC 24V |
| Wiring Method | Non-Polar, Two-Wire |
| Operating Temperature | -10°C to +50°C |
| Relative Humidity | ≤95% (Non-Condensing) |
| Weight | Approx. 70g (without base) |
| Weight with Base | Approx. 110g |
| Base Type | DZ-912 |
| Ingress Protection Rating | IP30 |
| Dimensions | Ø100mm × 47mm (without base) |
| Dimensions with Base | Ø100mm × 60mm |
| Status Indication | Red LED Blinking During Monitoring |
| Alarm Indication | Red LED Steady ON During Alarm |
Conventional Fire Alarm System
A flexible EN 54 control panel for small to medium sites, supporting up to 16 zones.
View details
Product details
The SEC3016C Conventional Fire Alarm Control Panel is a versatile and reliable solution designed for small to medium-sized applications. Supporting multiple zone configurations and up to 32 devices per zone, the panel offers flexible system design while simplifying installation through its two-wire architecture. Four sounder outputs, repeater communication support, and EN 54 compliance provide dependable alarm management for a wide range of facilities.
| Model | SEC3016C |
|---|---|
| Product Type | Conventional Fire Alarm Control Panel |
| Standards | EN 54-2 & EN 54-4 |
| Zone Configurations | 2 / 4 / 8 / 12 / 16 Zones |
| Zone Capacity | Up to 32 Devices per Zone |
| Mains Supply | 110/230V AC (-15%, +10%), 50Hz/60Hz |
| Power Supply Rating | 26.5V–28.5V DC ±0.5V |
| Battery Charge Current | 0.4A Max |
| Recommend Battery | 7Ah VRLA (NP7-12 Yuasa) |
| Battery Fuse | 3A |
| Max Internal Battery Resistance | 1.5Ω |
| Quiescent Current | ≤0.1A |
| Zone Voltage | 20V–28V DC |
| Zone Alarm Current Threshold | 15mA |
| Sounder Alarm Outputs | 4 × 150mA @ 24V DC |
| Sounder End of Line | 10KΩ, 1W |
| Fire Relay | 1 × Volt Free Relay, 2A @ 30V DC Max |
| Fault Relay | 1 × Volt Free Relay, 2A @ 30V DC Max |
| Construction | 1.0mm Mild Sheet Steel |
| Flame Retardant Rating | V2 |
| IP Rating | IP30 |
| Dimensions (W×H×D) | 380 × 340 × 105 mm |
| Weight (Without Battery) | 5 kg |
| Operating Temperature | -10°C to +55°C |
| Relative Humidity | 95% (Non-Condensing) |